热水管无水放出(保温箱无水),济南力诺瑞特太阳能电控制箱内置液位控制器无输出(红灯不亮)排除方法:

The hot water pipe release (incubator anhydrous anhydrous), Ji'nan linuoruite solar electric control box built-in level controller without output (red light) elimination method:

先检查副水箱是否有冷水,如有,再检查控制箱内空开和漏电开关是否跳开,如好再检查液位控制器电源电源指示绿灯是否亮,如不亮应检查接线模板从左边数一和第二接线是否有220V电源.

Check whether there is a cold water tank, if any, and then check the control box and the air leakage switch is tripped, as well and then check the power indicator light power level controller is bright, if not bright should check the wiring template from the left first and second wiring is 220V power supply.

如没有应依次往上测查;如液位控制器绿灯亮,红灯不亮,应先把接线模板上右边第二和第三的高低水位线拆除,此时如无输出或红灯亮无输出(交流接触器不启动),应检查或更换液位控制器.

If there is no should turn up test; such as liquid level controller of green light, red light, should be removed second and third of the water level on the right line connection template, if no output or red light output (AC contactor start), should check or replace the liquid level controller.

如有输出则应检查水位探头两线间是否有锈蚀短路或结垢,清理修复或更换水位线及探头。排除方法:

If there is an output, it should check whether there is corrosion, short circuit or scaling between the two probes of the water level probe, and clean, repair or replace the water level line and probe. Elimination method:

济南力诺瑞特太阳能多少钱

(1)检查接触器线圈引线和接线板上的接线是否接触良好。

(1) check whether the wiring of contactor coil lead and wiring board is in good contact.

(2)先断开电源,用一根导线取代超温保护引线第2、4联通后,接通电源,接触器吸合,则检查是否因冷水缺水超温保护器已自动断开或烧坏;断开电源更换超温保护元件;如果接触器不吸合,断开电源去除接触器线圈引线,用万用表检查线圈,若线圈短路或断路,更换接触器,故障排除。

(2) first disconnect the power supply, with a wire to replace the overtemperature protection lead 2, 4 Unicom, the power supply is switched on, contactor, check whether the water shortage because of cold water thermostat is automatically disconnected or burn; disconnect the power to replace the overtemperature protection element; if the contactor is not closed, disconnect the power supply remove the contactor coil wire, with a multimeter to check if the coil, coil short circuit or open circuit, replace the contactor, troubleshooting.